Review




Structured Review

Stryker target tetra detachable coil
Axium Prime 3D <t>detachable</t> coil, Medtronic, Irvine, CA, USA; Excelsior SL-10, Stryker Neurovascular, Kalamazoo, MI, USA; Excelsior SL-10 Preshaped 45°, Stryker Neurovascular; PcomA, posterior communicating artery; Target XL 360 Soft detachable coil, Stryker Neurovascular
Target Tetra Detachable Coil, supplied by Stryker, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/target+%C2%AE+tetra%E2%84%A2+coils/coil+detachable+target+tetra/pmc12952529-116-6-10
Average 86 stars, based on 1 article reviews
target tetra detachable coil - by Bioz Stars, 2026-10
86/100 stars

Images

1) Product Images from "Efficacy and Limitations of Stent-Free Coil Embolization for Internal Carotid–Posterior Communicating Artery Aneurysms, Primarily Based on the Double-Catheter Technique: A Study Reflecting Current Endovascular Practice"

Article Title: Efficacy and Limitations of Stent-Free Coil Embolization for Internal Carotid–Posterior Communicating Artery Aneurysms, Primarily Based on the Double-Catheter Technique: A Study Reflecting Current Endovascular Practice

Journal: JNET Journal of Neuroendovascular Therapy

doi: 10.5797/jnet.oa.2025-0117

Axium Prime 3D detachable coil, Medtronic, Irvine, CA, USA; Excelsior SL-10, Stryker Neurovascular, Kalamazoo, MI, USA; Excelsior SL-10 Preshaped 45°, Stryker Neurovascular; PcomA, posterior communicating artery; Target XL 360 Soft detachable coil, Stryker Neurovascular
Figure Legend Snippet: Axium Prime 3D detachable coil, Medtronic, Irvine, CA, USA; Excelsior SL-10, Stryker Neurovascular, Kalamazoo, MI, USA; Excelsior SL-10 Preshaped 45°, Stryker Neurovascular; PcomA, posterior communicating artery; Target XL 360 Soft detachable coil, Stryker Neurovascular

Techniques Used:

Related Articles

other:

Article Title: Initial experiences with the target tetra coils: An illustrated case series
Article Snippet: 1 Among the latest technologies are the Target ® TetraTM coils (Stryker Neurovascular, Kalamazoo, MI, USA) which received United States Food and Drug approval for usage in 2022.



Similar Products

86
Stryker target tetra detachable coil
Axium Prime 3D <t>detachable</t> coil, Medtronic, Irvine, CA, USA; Excelsior SL-10, Stryker Neurovascular, Kalamazoo, MI, USA; Excelsior SL-10 Preshaped 45°, Stryker Neurovascular; PcomA, posterior communicating artery; Target XL 360 Soft detachable coil, Stryker Neurovascular
Target Tetra Detachable Coil, supplied by Stryker, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/target+%C2%AE+tetra%E2%84%A2+coils/coil+detachable+target+tetra/pmc12952529-116-6-10
Average 86 stars, based on 1 article reviews
target tetra detachable coil - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
Stryker target tetra 2-mm × 2.5-cm coil
Axium Prime 3D <t>detachable</t> coil, Medtronic, Irvine, CA, USA; Excelsior SL-10, Stryker Neurovascular, Kalamazoo, MI, USA; Excelsior SL-10 Preshaped 45°, Stryker Neurovascular; PcomA, posterior communicating artery; Target XL 360 Soft detachable coil, Stryker Neurovascular
Target Tetra 2 Mm × 2.5 Cm Coil, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/target+%C2%AE+tetra%E2%84%A2+coils/target+tetra+2+mm+%C3%97+2+5+cm+coil/pmc12210065-26-17-18
Average 90 stars, based on 1 article reviews
target tetra 2-mm × 2.5-cm coil - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Stryker target ® tetra™ coils
Axium Prime 3D <t>detachable</t> coil, Medtronic, Irvine, CA, USA; Excelsior SL-10, Stryker Neurovascular, Kalamazoo, MI, USA; Excelsior SL-10 Preshaped 45°, Stryker Neurovascular; PcomA, posterior communicating artery; Target XL 360 Soft detachable coil, Stryker Neurovascular
Target ® Tetra™ Coils, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/target+%C2%AE+tetra%E2%84%A2+coils/target+++tetra++coils/pmc12095262-24-7-11
Average 90 stars, based on 1 article reviews
target ® tetra™ coils - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

86
Stryker target tetra detachable coil ttdc
Details of case using <t> TTDC </t> for the 1st coil
Target Tetra Detachable Coil Ttdc, supplied by Stryker, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/target+%C2%AE+tetra%E2%84%A2+coils/coil+detachable+target+tetra/pmc12361705-17-4-9
Average 86 stars, based on 1 article reviews
target tetra detachable coil ttdc - by Bioz Stars, 2026-10
86/100 stars
  Buy from Supplier

90
Stryker target tetra × coil
Details of case using <t> TTDC </t> for the 1st coil
Target Tetra × Coil, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/target+%C2%AE+tetra%E2%84%A2+coils/target+tetra+%C3%97+coil/pmc12255218-35-13-13
Average 90 stars, based on 1 article reviews
target tetra × coil - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Stryker target tetra detachable coil (ttdc)
Target tetra <t>detachable</t> coil <t>(TTDC).</t> By maintaining a tetrahedral conformation inside an intracranial aneurysm, it is feasible to treat small aneurysms, which is advantageous, especially during the framing process. In addition, a braided stretch-resistant suture allows for a smoother delivery and reduced microcatheter kickback.
Target Tetra Detachable Coil (Ttdc), supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/target+%C2%AE+tetra%E2%84%A2+coils/target+tetra+detachable+coil++ttdc+/pmc11355286-74-2-7
Average 90 stars, based on 1 article reviews
target tetra detachable coil (ttdc) - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Stryker target tetra 360 detachable coil
Target tetra <t>detachable</t> coil <t>(TTDC).</t> By maintaining a tetrahedral conformation inside an intracranial aneurysm, it is feasible to treat small aneurysms, which is advantageous, especially during the framing process. In addition, a braided stretch-resistant suture allows for a smoother delivery and reduced microcatheter kickback.
Target Tetra 360 Detachable Coil, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/target+%C2%AE+tetra%E2%84%A2+coils/target+360+detachable+coils/pmc11042672-21-2-9
Average 90 stars, based on 1 article reviews
target tetra 360 detachable coil - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

90
Boston Scientific Corporation target tetra 360 detachable coil
Target tetra <t>detachable</t> coil <t>(TTDC).</t> By maintaining a tetrahedral conformation inside an intracranial aneurysm, it is feasible to treat small aneurysms, which is advantageous, especially during the framing process. In addition, a braided stretch-resistant suture allows for a smoother delivery and reduced microcatheter kickback.
Target Tetra 360 Detachable Coil, supplied by Boston Scientific Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/target+%C2%AE+tetra%E2%84%A2+coils/target+tetra+360+detachable+coil/pmc11042672-32-16-8
Average 90 stars, based on 1 article reviews
target tetra 360 detachable coil - by Bioz Stars, 2026-10
90/100 stars
  Buy from Supplier

Image Search Results


Axium Prime 3D detachable coil, Medtronic, Irvine, CA, USA; Excelsior SL-10, Stryker Neurovascular, Kalamazoo, MI, USA; Excelsior SL-10 Preshaped 45°, Stryker Neurovascular; PcomA, posterior communicating artery; Target XL 360 Soft detachable coil, Stryker Neurovascular

Journal: JNET Journal of Neuroendovascular Therapy

Article Title: Efficacy and Limitations of Stent-Free Coil Embolization for Internal Carotid–Posterior Communicating Artery Aneurysms, Primarily Based on the Double-Catheter Technique: A Study Reflecting Current Endovascular Practice

doi: 10.5797/jnet.oa.2025-0117

Figure Lengend Snippet: Axium Prime 3D detachable coil, Medtronic, Irvine, CA, USA; Excelsior SL-10, Stryker Neurovascular, Kalamazoo, MI, USA; Excelsior SL-10 Preshaped 45°, Stryker Neurovascular; PcomA, posterior communicating artery; Target XL 360 Soft detachable coil, Stryker Neurovascular

Article Snippet: Similarly, for aneurysms <3 mm, a Target Tetra detachable coil (Stryker Neurovascular) or a HydroSoft 3D detachable coil (MicroVention, Aliso Viejo, CA, USA) is often selected as the first coil.

Techniques:

Journal: Surgical Neurology International

Article Title: Use of Target Tetra with an understanding of its novel structure

doi: 10.25259/SNI_401_2025

Figure Lengend Snippet: Details of case using TTDC for the 1st coil

Article Snippet: [ ] Recently, the Target Tetra detachable coil (TTDC) (Stryker Neurovascular, Fremont, CA, the USA) has become available for use in cerebral aneurysm coil embolization.

Techniques:

In the case of a ruptured anterior communicating artery aneurysm, the height, width, and neck size of the aneurysm were 2.7, 2.8, and 2.7 mm, respectively. (a) Angiography before embolization. (b) Attempted frame formation using Target Ultra 2.5 mm × 4 cm. Safe frame formation was not possible due to protrusion into the parent artery. (c) A 2.5 mm × 3.5 cm Target Tetra detachable coil (TTDC) was placed through the aneurysmal neck. (d) A 2.0 mm × 2.5 cm TTDC was implanted as the second coil. The aneurysm neck was packed tight. However, the aneurysm tip had a space (arrow). (e) Angiography after completing embolization. The aneurysm, including its tip, had disappeared.

Journal: Surgical Neurology International

Article Title: Use of Target Tetra with an understanding of its novel structure

doi: 10.25259/SNI_401_2025

Figure Lengend Snippet: In the case of a ruptured anterior communicating artery aneurysm, the height, width, and neck size of the aneurysm were 2.7, 2.8, and 2.7 mm, respectively. (a) Angiography before embolization. (b) Attempted frame formation using Target Ultra 2.5 mm × 4 cm. Safe frame formation was not possible due to protrusion into the parent artery. (c) A 2.5 mm × 3.5 cm Target Tetra detachable coil (TTDC) was placed through the aneurysmal neck. (d) A 2.0 mm × 2.5 cm TTDC was implanted as the second coil. The aneurysm neck was packed tight. However, the aneurysm tip had a space (arrow). (e) Angiography after completing embolization. The aneurysm, including its tip, had disappeared.

Article Snippet: [ ] Recently, the Target Tetra detachable coil (TTDC) (Stryker Neurovascular, Fremont, CA, the USA) has become available for use in cerebral aneurysm coil embolization.

Techniques:

In the case of an unruptured internal carotid artery-paraclinoid medial-type aneurysm, the height, width, and neck size of the aneurysm were 3.0, 4.5, and 3.0 mm, respectively. (a) Angiography before embolization. The balloon catheter was seated on the aneurysm neck. (b) The frame was formed with the first coil. The arrow was a microcatheter tip. (c-f) The Target Tetra detachable coil (TTDC) was implanted deep inside the aneurysm. Each arrow was a gradual kicking back microcatheter tip. The TTDC sizes were 3 mm × 4.5 cm (c), 3 mm × 4.5 cm (d), 2.5 mm × 4.5 cm (e), and 2 mm × 2.5 cm (f). (g) Angiography after completing embolization. The aneurysm had disappeared.

Journal: Surgical Neurology International

Article Title: Use of Target Tetra with an understanding of its novel structure

doi: 10.25259/SNI_401_2025

Figure Lengend Snippet: In the case of an unruptured internal carotid artery-paraclinoid medial-type aneurysm, the height, width, and neck size of the aneurysm were 3.0, 4.5, and 3.0 mm, respectively. (a) Angiography before embolization. The balloon catheter was seated on the aneurysm neck. (b) The frame was formed with the first coil. The arrow was a microcatheter tip. (c-f) The Target Tetra detachable coil (TTDC) was implanted deep inside the aneurysm. Each arrow was a gradual kicking back microcatheter tip. The TTDC sizes were 3 mm × 4.5 cm (c), 3 mm × 4.5 cm (d), 2.5 mm × 4.5 cm (e), and 2 mm × 2.5 cm (f). (g) Angiography after completing embolization. The aneurysm had disappeared.

Article Snippet: [ ] Recently, the Target Tetra detachable coil (TTDC) (Stryker Neurovascular, Fremont, CA, the USA) has become available for use in cerebral aneurysm coil embolization.

Techniques:

In the case of a ruptured vertebral artery-posterior inferior cerebellar artery aneurysm, the height, width, and neck size of the aneurysm were 3.7, 4.7, and 2.8 mm, respectively. (a) Angiography before embolization. (b) The first coil was implanted with Target 360 Ultra 4 mm × 8 cm. (c) The microcatheter tip perforated the aneurysm during the second coil, with a 3.5 mm × 6 cm Target Tetra detachable coil (TTDC). (d and e) A 2.5 mm × 6 cm TTDC was implanted from the outside of the aneurysm to the inside. However, bleeding was observed (arrow). (f and g) The last coil, which is a 2 mm × 2.5 cm TTDC, stopped the bleeding.

Journal: Surgical Neurology International

Article Title: Use of Target Tetra with an understanding of its novel structure

doi: 10.25259/SNI_401_2025

Figure Lengend Snippet: In the case of a ruptured vertebral artery-posterior inferior cerebellar artery aneurysm, the height, width, and neck size of the aneurysm were 3.7, 4.7, and 2.8 mm, respectively. (a) Angiography before embolization. (b) The first coil was implanted with Target 360 Ultra 4 mm × 8 cm. (c) The microcatheter tip perforated the aneurysm during the second coil, with a 3.5 mm × 6 cm Target Tetra detachable coil (TTDC). (d and e) A 2.5 mm × 6 cm TTDC was implanted from the outside of the aneurysm to the inside. However, bleeding was observed (arrow). (f and g) The last coil, which is a 2 mm × 2.5 cm TTDC, stopped the bleeding.

Article Snippet: [ ] Recently, the Target Tetra detachable coil (TTDC) (Stryker Neurovascular, Fremont, CA, the USA) has become available for use in cerebral aneurysm coil embolization.

Techniques:

Target tetra detachable coil (TTDC). By maintaining a tetrahedral conformation inside an intracranial aneurysm, it is feasible to treat small aneurysms, which is advantageous, especially during the framing process. In addition, a braided stretch-resistant suture allows for a smoother delivery and reduced microcatheter kickback.

Journal: Journal of Clinical Medicine

Article Title: Endovascular Embolization of Intracranial Aneurysms Using Target Tetra Detachable Coils: Angiographic and Clinical Results from a Single Center

doi: 10.3390/jcm13164940

Figure Lengend Snippet: Target tetra detachable coil (TTDC). By maintaining a tetrahedral conformation inside an intracranial aneurysm, it is feasible to treat small aneurysms, which is advantageous, especially during the framing process. In addition, a braided stretch-resistant suture allows for a smoother delivery and reduced microcatheter kickback.

Article Snippet: Recently, a target tetra detachable coil (TTDC) (Stryker Neurovascular, Fremont, CA, USA) was introduced ( ).

Techniques:

A 59-year-old male patient with an unruptured right posterior communicating artery aneurysm. ( A ) Three-dimensional rotational angiography shows a left posterior communicating artery aneurysm (neck: 5.0 mm, height: 5.8 mm, size: 7.8 × 5.1 mm). ( B ) The Target 360 Ultra coil of the appropriate size was initially selected as the framing coil. However, the coil expanded outside the aneurysmal sac and protruded into the parent artery, obliterating the posterior communicating artery (arrow). A new frame was established using the TTDC.

Journal: Journal of Clinical Medicine

Article Title: Endovascular Embolization of Intracranial Aneurysms Using Target Tetra Detachable Coils: Angiographic and Clinical Results from a Single Center

doi: 10.3390/jcm13164940

Figure Lengend Snippet: A 59-year-old male patient with an unruptured right posterior communicating artery aneurysm. ( A ) Three-dimensional rotational angiography shows a left posterior communicating artery aneurysm (neck: 5.0 mm, height: 5.8 mm, size: 7.8 × 5.1 mm). ( B ) The Target 360 Ultra coil of the appropriate size was initially selected as the framing coil. However, the coil expanded outside the aneurysmal sac and protruded into the parent artery, obliterating the posterior communicating artery (arrow). A new frame was established using the TTDC.

Article Snippet: Recently, a target tetra detachable coil (TTDC) (Stryker Neurovascular, Fremont, CA, USA) was introduced ( ).

Techniques: